12 Lubricants for four-stroke engines
High melting-point greases
High-temperature grease (up to 250 °C) must be used for emergency shutoff flaps located
between turbocharger and intercooler:
• Aero Shell Grease 15
• Optimol Inertox Medium
General purpose greases suffice for emergency air shutoff flaps located before the turbocharger or after the intercooler.
Greases for internal centerings of couplings
Greases for internal centerings:
• Esso Unirex N3 (stable up t o approx. 160 °C)
Special-purpose lubricants
Turbochargers
Exhaust turbochargers w ith integrated oil supply are generally connected to the engine oil system.
For ABB turbochargers which are not connected to the engine lube oil system, mineral-based
turbine oils with viscosity grade ISO-VG 68 must be used.
Gear couplings
Depending on the application, the following lubricants have been approved for curvic gear couplings:
• - Klüber: Structovis BHD MF (highly viscous lubricating oil)
• - Klüber: Klüberplex GE11–680 (adhesive transmission lubricant)
Guidelines on use and service life are contained in the relevant Operating Instructions and Maintenance Schedules.